TechnoSonus Floor

Product Description

TechnoSonus Floor is a special bitumen-polymer rolled material with a sound insulation layer of polyester felt. The combination ensures sound- and waterproofing of premises. The material is used in floating floor construction for protection against noise impact.

Application

Composition

  • bitumen-polymer binder
  • glass-fibre mat
  • synthetic felted fabric
Modifications
Characteristics
Storage and transportation
Modifications
ModificationsTechnoSonus Floor
Length, mm*
10000
Width, mm*
1000
Thickness, mm*
4.5
Weight of m2, kg*
2.3
Roll Weight, kg*
23

* Length: 10m (±200 mm), Width: 1 m (±30 mm), Thickness: 4.5 mm (±0.8 mm)

Characteristics
ParameterTechnoSonus Floor
Impact Sound Insulation Improvement Index, ΔLnw, dB
27
Force at Rupture (length), H/50mm
min / real
400 / 432
Surface Density, kg/m2
2.3 ± 0.3
Heat Distortion Temperature (minimum), °С
85
Waterproofing Capacity, MPa
absolute
Material operating temperature
up to -5°C
Storage period*
24 months

* subject to storage and transportation conditions.

After the warranty period of storage has expired, the products must be checked for compliance with the declared characteristics and, if they comply with the declared characteristics, the period of storage may be extended.

Storage and transportation
ModificationsTechnoSonus Floor
Packing type
pallet
Package size (LxWxH), mm
1200 х 1000 х 1500
No. of Rolls per Pallet, pcs
20
Pallet Weight, kg
460 ± 60
Pallet Volume, m3
1.38
82 m3 Euro Trailer Loading Capacity, pallet, pcs
26
82 m3 Euro Trailer Loading Capacity, rolls, pcs
520

The products shall be stored vertically on pallets. Placement of pallets on one another is not allowed.

The products shall be stored and transported under conditions that protect them from mechanical damage, direct sunlight, precipitation and other destructive substances.

By agreement with the consumer, other storage and transportation conditions are allowed if additional measures are taken to prevent damage to the product.

The products shall be stored in original packages away from sources of heat and UV radiation in a dry place at max. 35°C.

IMPORTANT! If the products are stored at a temperature below 5°C, it is necessary to keep the products indoors for at least 24 hours at room temperature before installation.